Bitfocus AS
logo
logo
Bitfocus AS
logo
logo
Sign upSign in

Loading...

Bitfocus

Subscribe to our newsletter

The latest news, articles, and resources, sent to your inbox.

FacebookInstagramGitHubYouTubeLinkedIn

Products

  • Buttons
  • Companion

Integrations

  • Supported Devices
  • Developer Community
  • Connection Development

Support

  • Support Overview
  • Documentation
  • Video Tutorials
  • Community Forum

Sales

  • Resellers & Integrators
  • Buttons Pricing

Updates

  • Case Studies
  • Events & Trade Shows
  • Press Releases
  • Product Updates
  • Webinars

Legal

  • Legal Overview
  • Privacy Policy
  • Buttons EULA
  • Terms & Cookie Policy

Company

  • About us
  • Press kit
  • Careers

© 2026 Bitfocus AS. All rights reserved.

  1. Connections
  2. Sennheiser - EM2, EM2 Dante, EM4 and more

Sennheiser

EM2 · EM2 Dante · EM4 · CHG70N · CHG70N-C

Communityv1.0.7Updated 4 weeks agoAudio
DocumentationReport an issueView on GitHub

Documentation

Sennheiser EW DX Series

Getting started

Just select the device from the module config window and enter the control IP of your EM2/EM4 receiver or network charger and press 'Save'. To control multiple devices, just add the connection several times to your Companion instance. For receivers with firmware >= 4.0.0 : please enable the "Legacy Mode" in the Sennheiser WSM Software for the receiver, to be able to control the devices using the SCP v1 protocol. If this is not done, you can't control your devices via Companion at this point.

Variables

This module stores pretty much all information the connected devices provide - some of them are available as feedbacks - but not all of them! So make sure to explore the "Variables" tab in Companion, to get an overview about all available information (e.g. Mounted Capsule on SKM, Battery charging cycles, transmitter type, etc.)

EM2/EM4 Status Display Explanation

In the module presets you will find a status display for every receiver channel of your device. It contains the following information:

  • Battery Percentage
  • Receiver channel name
  • Frequency
  • RSQI

Beside this information the following icons are used:

AF Peak AF Peak

Warning Warning - one or more warnings are currently present on the receiver channel

Encryption Disabled Encryption - Disabled

Encryption Enabled Encryption - Enabled

Encryption Error Encryption - Error (for example because Encryption was disabled and enabled again without syncing the transmitters again)

Mute Muted - Either the transmitter or receiver is muted

RSQI Green RSQI - Good signal (> 70%)

RSQI Yellow RSQI - Medium signal (> 40%)

RSQI Red RSQI - Bad signal (>= 1%)

RSQI Grey RSQI - No signal / No RSQI information (0%)

Ant A Antenna - A is currently receiving

Ant B Antenna - B is currently receiving

Battery Battery - Shows the remaining battery percentage (> 50% Green, >= 20% Yellow, < 20% Red)

When the RX identification is active (either by triggering from Companion or by pressing the Power Button on a transmitter), a green bar at the bottom of the button is shown. If you are using the preset, the identify action will be already assigned to the button.

CHG 70N Status Display Explanation

In the module presets you will find a status display for every charging bay of your device. It contains the following information:

  • Battery charging Percentage
  • Remaining charging time (in minutes)
  • Device Type (which device is currently being charged: SKM, BA70, etc.)

Beside this information the following icons are used:

Warning Warning - one or more warnings are currently present on the charging bay

Charging Error Charging Error - The battery can either not get charged or discharged

Communication Error Communication Error - The charger can't communicate with the battery

Temperature Error Temperature Error - The battery temperature is outside of the supported range (either too cold or too hot)

Overcurrent Error Overcurrent Error - An overcurrent was detected

Green Dot Bay State: normal

Red Dot Bay State: not normal - the current bay state is either UPDATE, ERROR, or DFU_MODE

When the bay identification is active, a green bar at the bottom of the button is shown. If you are using the preset, the identify action will be already assigned to the button.

Details

Manufacturer
Sennheiser
Products
EM2, EM2 Dante, EM4, CHG70N, CHG70N-C
Latest Version
v1.0.7
Author
Leon Reucher
Contributors
leonreucher(39)
jmcc94(10)
leroygitgit(2)
jonasschnaitmann(1)

Open Issues and Requests

phillipivan#40 fix: make sure advanced feedbacks scale to supplied image size.mikewood-larian#32 [BUG] Using Companion v5.0.2 and Sennheiser: EM2; EM2 Dante; EM4; CHG70N; CHG70N-C v1.06 the EWDX Status feedback does not displayjmcc94#5 Sound Control Protocol v2 (SSCv2)

To file a new issue, you need to sign up for a user on GitHub.

Go to GitHub issues →

In other news

Buttons v1.8 Main with text

Buttons v1.8

October 2, 2026

Buttons v1.8 IBC award win

Bitfocus wins IBC2026 Best of Show Award for latest Buttons enhancements

September 21, 2026

Buttons v1.8 grey background

Biggest functionality boost yet makes Buttons the perfect platform for broadcast and media management

September 10, 2026

Vivid Buttons on screen

Bitfocus Buttons makes complex OB production feel simple

August 10, 2026

View all news →

More from Sennheiser

EM 6000 · EM 6000 Dante · L 6000

Sennheiser

Community
Audio
View Connection

Spectera

Sennheiser

Elite
AudioDante
View Connection