Bitfocus AS
logo
logo
Bitfocus AS
logo
logo

Loading...

Bitfocus

Subscribe to our newsletter

The latest news, articles, and resources, sent to your inbox.

FacebookInstagramGitHubYouTubeLinkedIn

Products

  • Buttons
  • Companion

Integrations

  • Supported Devices
  • Developer Community
  • Connection Development

Support

  • Support Overview
  • Documentation
  • Video Tutorials
  • Community Forum

Sales

  • Resellers & Integrators
  • Buttons Pricing

Updates

  • Case Studies
  • Events & Trade Shows
  • Press Releases
  • Product Updates
  • Webinars

Legal

  • Legal Overview
  • Privacy Policy
  • Buttons EULA
  • Terms & Cookie Policy

Company

  • About us
  • Press kit
  • Careers
Co-funded by the European Union

Our Bitfocus Workflow 2.0 project is co-funded by the European Union’s Creative Europe programme. About the project

© 2026 Bitfocus AS. All rights reserved.

  1. Connections
  2. twoloox - Pandoras Box

twoloox

Pandoras Box

Communityv3.1.7Updated 23 hours ago
DocumentationReport an issueView on GitHub

Documentation

twoloox Pandoras Box

Controls twoloox Pandoras Box media servers (V8 and newer) via the PandorasAutomation (PBAU) TCP protocol.

Requires Companion 5.0 or later. For older Companion versions, use module version 3.0.1.

Configuration

  • Target IP: IP address of the Pandoras Box server (e.g. 192.168.1.100). The module always connects to port 6211, the PandorasAutomation port.
  • Domain: Pandoras Box domain, default 0. If the connection stays in an error state, check that the domain matches.
  • Log protocol traffic (debug): Off by default. For troubleshooting, enable it and set the connection's log level in Companion to Debug to log every message sent and received.

After connecting, the module finds all sequences by itself and keeps the list up to date every 10 seconds. If the connection drops, or Pandoras Box stops answering for about 5 seconds (e.g. a network cable was pulled), it reconnects automatically every 3 seconds. Changing the Target IP or Domain takes effect immediately, so switching between a main and a backup server takes well under a second when both are running.

Actions

Sequences

  • Sequence Transport: Play, Pause or Stop a sequence.
  • Toggle Sequence Play/Pause
  • Goto Cue: jump to a cue by its ID.
  • Goto Next/Last Cue
  • Ignore Next Cue
  • Set Playhead: move a sequence to a time, see below.
  • Sequence Opacity Fade: fade a sequence to a target opacity (0-100 %) over a time in milliseconds. Curves: Linear (recommended), Ease In, Ease Out, Ease In-Out, S-Curve. Triggering it again on the same sequence replaces the running fade.
  • Set Sequence SMPTE Timecode Mode: None, TC Send or TC Receive.
  • Select Sequence (Edit)
  • Refresh Sequence List: reload the sequence list right away instead of waiting for the next automatic refresh.

Programming

  • Store Active to Sequence
  • Store Active to Container Beginning
  • Clear All Active
  • Reset All Values

Project and sites

  • Save Project
  • Toggle Fullscreen (Site ID)
  • Set Site IP by ID
  • Recall GUI View

Connection

  • Switch Server (Target IP and Domain): connects to another Pandoras Box server, see below.

Switch Server

  • Connects to the given Target IP and Domain and saves them as the new connection setting, the same as entering them in the connection settings and pressing Save.
  • For main/backup switching, put the action on two buttons: one with the main server, one with the backup server. When both servers are running, the switch takes well under a second.
  • At your own risk: pressing the button immediately disconnects from the current server. The action only runs when the field "Type YES to confirm" contains exactly YES.
  • Invalid IP addresses (only IPv4, no computer names) and invalid domains are ignored and logged as a warning, nothing changes.

Set Playhead

  • Absolute moves the sequence to the given time, Relative moves it forward (+) or back (-) from its current position.
  • Timecode is read from the right like SMPTE timecode: the last group is always frames, then seconds, minutes and hours. Missing groups count as 0.
InputMeans
01:01:01:011 hour 1 minute 1 second 1 frame
01:00:101 minute 0 seconds 10 frames
01:001 second 0 frames
1010 frames (digits without colons are read in pairs from the right)
1001 second
100010 seconds
130001 minute 30 seconds
2h3m5s2 hours 3 minutes 5 seconds (units in the order h, m, s, f)
90s1 minute 30 seconds
120m90s2 hours 1 minute 30 seconds
5s10f5 seconds 10 frames
-500 or -5s5 seconds back (Relative mode)
  • Units: only h, m, s and f (frames), in this order and each at most once. Larger values are converted, as in 90s or 120m90s. Frames are sent as entered, because the module doesn't know the sequence's frame rate.
  • The field accepts variables and expressions. Input with spaces (also at the start or end), other units such as ms, decimals such as 10.5 or 1.5m and any other text are ignored, nothing is sent.
  • Learn fills in the sequence's current time and sets the mode to Absolute.
  • In Companion, hover over the field for these rules and examples.

Feedbacks

  • Sequence transport state matches: active while the selected sequence is in the selected state (Play, Pause or Stop).
  • Remaining cue under threshold: active while the time until the next cue of the selected sequence is at or below the threshold in seconds.

Variables

Replace <id> with the sequence ID and pandorasbox with your connection's label, e.g. $(pandorasbox:sequence_2_time).

VariableContent
sequence_<id>Sequence name
sequence_<id>_statusPlay, Pause, Stop or Unknown
sequence_<id>_timeCurrent time hh:mm:ss:ff, parts in _hh, _mm, _ss, _ff
sequence_<id>_countdownTime until the next cue, parts in _countdown_hh, _countdown_mm, _countdown_ss, _countdown_ff
sequence_<id>_countupTime since the previous cue, parts in _countup_hh, _countup_mm, _countup_ss, _countup_ff
sequence_<id>_nextcueNext cue as Name (Mode ID), parts in _nextcue_name, _nextcue_id, _nextcue_mode
sequence_<id>_prevcuePrevious cue as Name (Mode ID), parts in _prevcue_name, _prevcue_id, _prevcue_mode
sequence_<id>_opacityOpacity in percent (0-100)
  • Cue mode letters: C = Play (continue), S = Stop, P = Pause, J = Jump, W = Wait.
  • Without a next or previous cue, the cue variables show No Cue (-) and -.
  • Without data, e.g. while disconnected, the countdown, countup and opacity variables show --, the time shows 00:00:00:00 and the status shows Unknown.
  • Time variables update up to 30 times per second while a sequence plays, 5 times per second otherwise.

Presets

  • Per sequence: Select (Edit), SMPTE Off, SMPTE Send, SMPTE Receive.
  • General presets for transport, cues, programming and the application. They use sequence 1, site 1 or view 1; adjust the options after placing them.

Known limitations

  • Cues can't be listed from Pandoras Box, so cue IDs have to be entered by hand.
  • The SMPTE mode can't be read back from Pandoras Box.
  • The module doesn't know a sequence's frame rate. The frames part of _countup_ff shows the sequence's current frame, and relative Set Playhead moves don't carry frames over into seconds.

Tested versions

  • Companion: 5.0.5
  • Pandoras Box: 8.11.3

Support

For issues and feature requests, contact twoloox GmbH or open an issue at https://github.com/bitfocus/companion-module-twoloox-pandorasbox/issues.

Details

Manufacturer
twoloox
Product
Pandoras Box
Latest Version
v3.1.7
Author
Daniel Kaminski
Contributors
robertskiba(33)
twoloox-kaminski(30)

Open Issues and Requests

To file a new issue, you need to sign up for a user on GitHub.

Go to GitHub issues →

In other news

Buttons v1.10 Release

Even more boosts for efficiency, reliability and security in latest Buttons release

November 23, 2026

Buttons v1.10 MCP webinar

Webinar Buttons v1.10 - MCP

November 17, 2026

Security Advisory

Buttons Security Advisory - CVE-2026-111497

October 26, 2026

Webinar Buttons v1.8

Webinar Buttons v1.8 Release

October 13, 2026

View all news →