This module is for control of Peavy NION DSPs. The RATC v1, v2, and v2 RAW modes are supported. All testing performed against Nion's running firmware 2.0. The selected protocol version must match your DSP's configuration. RATC v2 is more powerful, offering relative changes, multiple change groups, and a keep alive. It should be used preferentially unless RATC v1 is required for compatibility reasons. Similarly, RATCv2 offers a better experience than RATCv2 RAW unless control of an arbitrarily large number of aliases is required, or the system can't be changed due to other dependencies.
This module may work with older Media Matrix units in RATCv1 mode, however this is untested and unsupported.
Requires Companion 5.1 or later.
Host
Enter the hostname or IP address of the DSP.
Port
This should normally remain 1632.
Username / Password
The RATC protocol specifies that a login must be performed after connection before control is allowed. This is transmitted in plain text. The password is stored as a secret, so Companion does not show it once entered.
In nWare ensure that the user account has Network Control Access set to allowed.
Use V2
Disable to use RATC v1 commands.
Most actions require reference to a control alias. The module will auto query and build a drop-down list of the control aliases upon connection. You may enter a custom alias if working offline, or switch the field to an expression to build the alias from variables. Refer to Peavy's External Control User Guide for further details.
All control aliases in use are added to the default change group so they can be polled periodically. If you use a variable without an associated action, you should manually add it to the default change group.
To create a toggle button, use the Control Position Invert action (RATCv2 only), and set its position to an expression reading the control's position variable.
Actions can only be sent while logged in to the DSP. An action run while the module is disconnected fails, rather than being sent later.
The detected control aliases, their values & positions (RATCv2) are returned as variables. In variable names, any character Companion does not allow, such as a space or /, is replaced with _. Values are kept as strings and retain their units; positions are converted to a number. Note: Returned strings containing whitespace will be truncated at the first whitespace, unless the DSP encloses them in quotes.
Variables are not defined when in RATC v2 RAW mode to preserve system resources. They can still be referenced if you follow the pattern $(yourModuleName:controlAliasValue_rawAlias) or $(yourModuleName:controlAliasPosition_rawAlias), with each / in the raw alias replaced by _. I.e., $(Nion_N3:controlAliasValue___devices_10_controls_hold_time). They will not have a value assigned until used by an action.
No feedbacks are provided. The native Internal Variable Check Value feedback is suitable for common feedback tasks such as mute tally when provided with a controls value or position variable.
The Action Recorder will translate any received numeric valueIs messages into Control Position Set (if RATCv2) or Control Set actions.