Documentation
Panasonic - AV-HS6000
Companion module to control Panasonic AV-HS6000 video mixer via TCP/IP connection.
Setup
-
Network Configuration
- Connect your Panasonic AV-HS6000 to the same network as your Companion system
- Note the IP address of your AV-HS6000 mixer
- Ensure the mixer's external control interface is enabled
-
Module Configuration
- Mixer IP: Enter the IP address of your AV-HS6000 mixer (default: 192.168.0.10)
- Mixer Port: TCP port for communication (default: 62000)
- Auto Refresh: Enable automatic status refresh from mixer
- Refresh Timing: Interval in seconds for bus status refresh (0-30 seconds)
- Source Name Refresh: Interval in seconds for source name updates (10-120 seconds)
- Timeout: Connection timeout in seconds (5-500 seconds)
Features
Bus Control
- ME1: Program, Preview, and 4 Keyers (Fill/Self)
- ME2: Program, Preview, and 4 Keyers (Fill/Self)
- DSK: 3 Downstream Keyers (Fill/Self)
- AUX: Multiple auxiliary outputs
Available Actions
- Set Bus Source: Assign input sources to various mixer buses
- Bus Operations: Control crosspoint assignments for all mixer buses
Feedbacks
- Bus Status: Visual feedback showing current source assignments
- Connection Status: Indicates if the module is connected to the mixer
Variables
- Dynamic variables for current bus assignments and mixer status
- Source names (when available from mixer)
Supported Buses
ME1 (Mix Effects 1)
- PGM (Program)
- PRW (Preview)
- KEY1-F/S through KEY4-F/S (Keyer Fill/Self)
- UTIL1/UTIL2 (Utility buses)
ME2 (Mix Effects 2)
- PGM (Program)
- PRW (Preview)
- KEY1-F/S through KEY4-F/S (Keyer Fill/Self)
- UTIL1/UTIL2 (Utility buses)
DSK (Downstream Keyers)
- DSK 1-F/S through DSK 3-F/S (Fill/Self)
AUX Outputs
- AUX 1 through AUX 24
Troubleshooting
Connection Issues
-
Check Network Connection
- Verify the mixer IP address is correct
- Ensure both devices are on the same network
- Check that port 62000 is not blocked by firewalls
-
Mixer Configuration
- Verify external control is enabled on the AV-HS6000
- Check the mixer's network settings
- Ensure the correct protocol is selected
-
Module Status
- Red status: Connection failed - check IP/port settings
- Yellow status: Connecting - wait for connection to establish
- Green status: Connected and operational
Performance Tips
- Set refresh timing to 0 to disable auto-refresh if not needed
- Use longer refresh intervals for better performance with multiple modules
- Monitor network traffic if experiencing delays
Protocol Information
This module implements the Panasonic AV-HS6000 external interface protocol over TCP/IP. For detailed protocol specifications, refer to the official Panasonic documentation.
Support
For issues with this module:
- Check the troubleshooting steps above
- Verify your mixer firmware version is compatible