AETA
HIFISCOOP 3 · SCOOP 3 · SCOOP 4+ · SCOOPY+ · Scoop5 S · +2 more
Communityv2.1.0-betaUpdated 3 months ago
Documentation
AETA Audio Codecs Module for Companion
This module allows control of AETA Audio Codecs through Companion.
Utilities folder contains reference files for developers as well as a dial pad companion page template for phones/codecs numbers input.
Configuration
- IP Address - The IP address of your AETA codec
- Port - The TCP port for AARC protocol (default: 6000)
- Password - AARC password if configured on the codec (leave blank if none)
- Enable Status Polling - Enable/disable automatic status updates
- Polling Interval - How often to poll for status updates (in milliseconds)
- Enable VU Meter - Enable/disable real-time VU meter monitoring
- VU Meter Interval - How often to poll for VU meter updates (in milliseconds)
Available Actions
Call Control
- Dial Number - Make a call to a specified number or SIP URI
Applicable units: all units - Hang Up - End the current call
Applicable units: all units
Audio Settings
- Set Input Gain - Adjust input gain (-12 to +12 dB)
Applicable units: HS3, S3, S4, S5, S+, SxS - Set Output Gain - Adjust output gain (-11 to +22 dBu)
Applicable units: all units - Set Coding Algorithm - Change the audio coding algorithm
Applicable units: all units - Set Coding Bit Rate - Change the audio bit rate
Applicable units: all units - Set Audio Interface Format - Select analogue or AES/EBU
Applicable units: HS3, S3, S4, S5, Scoop5 S, Scoop5 S-IP - Set AES Sync Mode - Set AES synchronization (genlock/master)
Applicable units: S4, S5, Scoop5 S, Scoop5 S-IP - Set AES Nominal Sampling Rate - Set AES interface sampling rate
Applicable units: S4, S5, Scoop5 S, Scoop5 S-IP - Set Input Impedance - Set analogue input impedance
Applicable units: S4, S5, Scoop5 S - Set Output Load - Set analogue output load
Applicable units: HS3, S3 - Set Channel Panning Mode - Set stereo panning
Applicable units: S+, Sy+ S - Set Output Signal Selection - Route output signal (send/receive/mix)
Applicable units: S+, Sy+ S - Set Input Attenuation Pad - Enable/disable input pad
Applicable units: S+, Sy+ S - Set Headphone Coordination Channel Routing - Configure headphone routing
Applicable units: S+, Sy+ S - Monitor Audio Levels - Start/stop periodic monitoring
Network Settings
- Set Network Type - Change network interface type
Applicable units: all units - Set IP Quality - Adjust IP streaming quality settings
Applicable units: S4, S5, S+, SxS - Set Packet Replication - Configure packet redundancy
Applicable units: S+, S5, SxS - Set DHCP Mode - Switch between DHCP and static IP
Applicable units: S4, S5, S+, SxS - Set IP Address - Set static IP address
Applicable units: S4, S5, S+, SxS - Set DNS Address - Set DNS server
Applicable units: S4, S5, S+, SxS - Set Gateway - Set default gateway
Applicable units: S4, S5, S+, SxS - Set Subnet Mask - Set subnet mask
Applicable units: S4, S5, S+, SxS
System Settings
- Set 5A System - Enable/disable 5A system
Applicable units: all units - Load Preset Configuration - Apply predefined settings:
Applicable units: all units (presets use multiple commands)- High Quality (Opus Stereo)
- Low Latency (G722)
- Mobile Data (Low Bandwidth)
- ISDN Backup Mode
- Refresh Data - Manual refresh of codec status
- Reset Device - Reboot the device
Applicable units: all units - Send Custom AT# Command - Send a custom AT# command
Applicable units: all units
Advanced/Other
- Set Dial Method - Select tone or pulse dialing
Applicable units: S+, S4, S5, SxS - Set Dial Tone - Wait for dial tone or not
Applicable units: S+, S4, S5, SxS - Set ISDN Call Filter - Set ISDN call filtering mode
Applicable units: all units - Set Proprietary ISDN Filter - Enable/disable proprietary ISDN filter
Applicable units: HS3, S3 - Set High Layer Capability (HLC) - Enable/disable HLC encoding
Applicable units: HS3, S3 - Set Auto Redial - Enable/disable auto redial for codec
Applicable units: S4, S5, S+, SxS - Set Redial Retries - Set number of redial attempts
Applicable units: S4, S5, S+, SxS - Set Redial Wait Time - Set wait time between redials
Applicable units: S4, S5, S+, SxS - Set Loop Control - Configure loop control for outgoing links
Applicable units: S4, S5, Scoop5 S, Scoop5 S-IP - Set Backup Network - Select backup network type
Applicable units: S4, S5, SxS - Set Passive Backup Mode - Enable/disable passive backup
Applicable units: S4, S5, SxS - Set Original/Copy Field (MPEG only) - Set MPEG original/copy field
Applicable units: HS3, S3 - Set Copyright Field (MPEG only) - Set MPEG copyright field
Applicable units: HS3, S3 - Set Error Correction/Protected Mode - Configure error correction
Applicable units: all units - Set Clock Mode (POTS) - Set POTS clock mode
Applicable units: S+, S5, SxS - Set Line Level (POTS) - Set POTS output line level
Applicable units: S+, S5, SxS - Set Speed (POTS) - Set POTS speed mode
Applicable units: S+, S4, S5, SxS - Set Data Channel - Enable/disable serial data channel
Applicable units: all units - Set Data Channel Baud Rate - Set baud rate for data channel
Applicable units: all units - Set Relay Transmission - Enable/disable relay transmission
Applicable units: all units - Set GPI State - Set General Purpose Input (GPI) state
Applicable units: S+, S4, S5, SxS - Set GPO State - Set General Purpose Output (GPO) state
Applicable units: S+, S4, S5, SxS - Set Auxiliary 3 kHz Audio Channel - Enable/disable auxiliary channel
Applicable units: HS3, S3, S4, S5 - Display Text Message - Send a text message to the device
Applicable units: S+, S4, S5, SxS
Available Feedbacks
Status Indicators
- Codec Connected - Changes color when codec has an established connection
- Ringing - Changes color when there's an incoming call
- Calling - Changes color during outgoing call attempt
- Call Established - Changes color when call is connected
- Call Released - Changes color when call is ended
Technical Monitoring
- Codec Alarms - Changes color when the codec has active alarms
- Audio Levels - Visual feedback for Tx/Rx audio levels
Variables
Connection Status
- Connection Status
- Codec Model
- Last Error Message
Call Status
- Ringing Status
- Calling Status
- Established Status
- Released Status
- Dial Number
- Local Number
Audio Settings
- Coding Algorithm
- Coding Bit Rate
- Audio Status
- Audio Level
- Input/Output Gain
- Tx Left Level
- Tx Right Level
- Rx Left Level
- Rx Right Level
Network Settings
- Network Type
- IP Quality
- Packet Replication
- Network Quality
- Jitter Buffer Status
System Status
- Active Alarms
- 5A System Status
- Configuration Number
- Test Loop Status
Network Configuration
- IP Address
- IP Mask
- Gateway
- DNS
- DHCP Mode
Supported Models
- HIFISCOOP 3
- SCOOP 3
- SCOOP 4+
- SCOOPY+
- SCOOP5 S
- SCOOP5 S-IP
- SCOOPY+ S
Error Handling
The module includes comprehensive error handling:
- Connection failures
- Authentication errors
- Invalid commands
- Network issues
- Audio problems
- Hardware alarms
Version History
Version 2.1.0-beta
- Added model filtering to actions and variables
Version 2.0.0-beta
- Major update to support Companion API 2.0
Version 1.1.2-beta
- Fixed states are now stored as booleans
- Fixed number/SIP field not being parsed properly
Version 1.1.1-beta
- Implemented real-time VU Metering (Tx/Rx Levels)
- Improved status reporting and error handling
Version 1.0.3-beta
- fixed call states feedbacks