# Send ATEM tally and labels to a UMD

> Set up a first end-to-end tally path from an ATEM switcher to a TSL multiviewer or UMD display, then verify it.

This guide creates a first end-to-end tally path from an ATEM connection to a TSL-compatible multiviewer or UMD display.

The finished path works like this:

```
ATEM Program or Preview state
→ Tally Provider for the affected ATEM input
→ Program or Preview Tally Channel on that source port
→ Tally Consumer watching an ATEM destination
→ TSL client connection
→ Multiviewer or UMD display
```

The Provider translates ATEM state into tally state inside Buttons. The Consumer watches a destination, follows its active source, resolves that source's label and Tally Channels, and sends the result to the external display.

## Before you begin

You need:

- A non-production ATEM connection that is online in Buttons.
- ATEM source and destination routing resources.
- A TSL-compatible multiviewer or UMD display.
- The display's IP address, TSL port, supported TSL version and transport, UMD address, and screen number where applicable.
- A destination that can be changed without affecting a production output.

This guide uses `Input 2` as the source and `ME 1 Program` as the destination. Substitute resources reserved for your own setup work.

<callout color="yellow" title="Warning">
  Consumer Test Mode sends output through the configured TSL connection. Use a non-production UMD address and make sure temporary labels or tally indications cannot be mistaken for live production state.
</callout>

## Create the Program and Preview channels

Tally Channels give operational meaning to tally state. In this setup, Providers activate **Program** or **Preview**, and Consumers map those channels to UMD indicators.

1. Open **Routing → Tally / UMD**.
2. Open **Channels**.
3. Select **Add**.
4. Under **Or quick add a preset**, select **Preview**.
5. Select **Add** again.
6. Select the **Program** preset.

The presets create:

- **Preview**, with short label **PVW** and a green color.
- **Program**, with short label **PGM** and a red color.

If these channels already exist, use the existing channels rather than creating duplicates. The switcher Quick Setup recognizes channels named `Program` and `Preview` and selects them for the corresponding ATEM roles.

## Create Providers from the ATEM

The ATEM knows whether each input contributes to Program or Preview. Quick Setup creates Providers that read those connection feedbacks and apply the matching Tally Channel to each ATEM source port.

1. Open **Providers**.
2. Select **Quick Setup**.
3. Select **Generate tally from a switcher (ATEM, etc.)**.
4. Under **Switcher Connection**, select the non-production ATEM.
5. Wait for Buttons to read the available inputs and Program/Preview suggestions.
6. Under **Program tally channels**, confirm **Program**.
7. Under **Preview tally channels**, confirm **Preview**.
8. Review the number of Providers that will be created.
9. Select **Create Providers**.

Quick Setup creates one Provider for each suggested input and each mapped role. Each Provider:

- Watches an ATEM Program or Preview feedback for one input.
- Uses the corresponding ATEM source port as its subject.
- Activates the selected Tally Channel when that feedback is active.

<callout color="green" title="Tip">
  Map only the Program and Preview roles you need. Quick Setup creates one Provider per input for every mapped role, so omitting an unused role avoids unnecessary Providers.
</callout>

## Confirm that ATEM tally reaches Buttons

Use a non-production ATEM route or switcher operation to place `Input 2` on the selected Program destination.

1. Open **Active** under **Tally / UMD**.
2. Find the `Input 2` source port.
3. Confirm that **Program** appears under **Active Channels**.
4. Confirm that the corresponding ATEM Provider appears under **Responsible Providers**.
5. Change the ATEM state away from `Input 2`.
6. Confirm that its Program tally clears or moves to the newly active source.

This proves the first half of the path: ATEM state is reaching a Provider and becoming a Tally Channel on the correct source port. It does not yet prove that the UMD output is configured.

## Create the TSL client connection

A TSL client connection sends labels and tally indications from Buttons to the multiviewer or UMD display.

1. Open **TSL Connections**.
2. Select **Add**.
3. Enter a **Label**, such as `Studio 2 Multiviewer`.
4. Set **Connection Type** to **Client (Connect)**.
5. Enter the display's IP address or hostname under **Host**.
6. Enter the display's TSL **Port**.
7. Select **Create**.
8. Open the new connection.
9. Under **Protocol**, select the TSL version and transport required by the display.
10. Save the connection.
11. Confirm that the connection does not show **Unconfigured** or **Error**.

New connections use TSL 5.0 UDP unless changed in the connection details. Match the display's configuration rather than assuming its protocol.

For UDP output, Buttons can transmit without receiving an acknowledgement from the display. A healthy connection status therefore does not prove that the display is using the messages; verify the result on the display itself.

## Create a Consumer for the UMD address

The Consumer watches `ME 1 Program`. Its **Active Source** lookups follow the current source routed to that destination. If `Input 2` is active there, the Consumer resolves the `Input 2` label and the Program or Preview channels attached to that source.

1. Open **Consumers**.
2. Select **Quick Setup**.
3. Select **Generate TSL outputs for ports / bundles**.
4. Select the TSL client connection created for the display.
5. Continue to the mapping step.
6. Select **Add Ports / Bundles**.
7. Select **Destinations**.
8. Choose **Bundles** or **Ports** to match how the display tile represents the signal.
9. Select the non-production `ME 1 Program` destination.
10. Select **Add Selected**.
11. Enter the UMD **Address** and **Screen** expected by the display.
12. Continue to **TSL UMD Setup**.
13. Leave **Resolved Label Preset** set to **Active Source**.
14. Leave **Resolved Tally Preset** set to **Active Source**.
15. Under **Tally Channel → TSL UMD**, confirm the intended mappings. By default, Buttons maps:

    - **Preview** to **Left** using the channel color.
    - **Program** to **Right** using the channel color.

16. Continue to **Review**.
17. Confirm the generated Consumer label.
18. Create the Consumer.

Use the UMD address and screen configured on the external display. The first generated mapping starts at address `0` and screen `0`, but those defaults are not a statement about the display's configuration.

## Verify the Consumer with Test Mode

Test Mode lets you verify the Consumer's label and tally mapping independently of current ATEM state. It drives the real configured output, so keep the test brief and identifiable.

1. Open **Consumers**.
2. Open the generated Consumer for `ME 1 Program`.
3. Turn on **Test Mode**.
4. Under the Program **Tally Lookup**, turn on **Active in test**.
5. Under **Label Lookups**, enter a clear **Test value**, such as `TALLY TEST`.
6. Save the Consumer.
7. Confirm that the intended UMD tile shows the test label and Program indication in the configured position and color.
8. Turn off **Test Mode**.
9. Save the Consumer again.
10. Confirm that the temporary test state clears from the display.

When no individual Tally Lookup is marked **Active in test**, Test Mode activates all configured Tally Lookups. Marking the Program lookup explicitly keeps this check limited to the intended indication.

## Verify the complete live path

After Test Mode is off:

1. Route `Input 2` to the non-production `ME 1 Program` destination.
2. Open **Active** and confirm that `Input 2` has the **Program** channel from the expected Provider.
3. Confirm that the UMD tile for `ME 1 Program` displays the resolved `Input 2` label.
4. Confirm that the Program indication appears in the configured UMD position and color.
5. Change the active source at `ME 1 Program`.
6. Confirm that both the resolved label and tally indication follow the new ATEM state.

This verifies each part of the signal flow:

- The ATEM supplies Program and Preview state.
- Providers assign Tally Channels to ATEM source ports.
- The Consumer follows the active source at the watched destination.
- The TSL client sends the resolved label and tally indication to the display.

## If the result is missing or incorrect

Check the path in order:

1. Under **Active**, confirm that the expected source port has the correct Tally Channel and Responsible Provider.
2. Open the Provider and confirm it is enabled and tied to the expected ATEM input and channel.
3. Open the Consumer and confirm its **Watch Item** is the intended destination.
4. Confirm the label and tally lookups use **Active Source**.
5. Confirm the Program and Preview channels map to the intended UMD positions and colors.
6. Confirm the Consumer's TSL output uses the intended connection, address, and screen.
7. Open **TSL Connections** and check the client connection status, host, port, protocol, and enabled state.
8. Confirm that the external display is configured for the same TSL version, transport, port, address, and screen.
9. Confirm **Test Mode** is off after setup work is complete.

If **Active** shows the correct source and channel but the display does not update, focus on the Consumer, TSL connection, and display configuration. If **Active** is already wrong, correct the ATEM Provider side before investigating the UMD output.